Pressure ratings

Pressure ratings - PE 100
The indicated operating pressures apply for an operating temperature of 20°C.
SDR |
S |
PN Pipe |
||||||||
Diameter- wall thickness ratio | Pipe series | Water max. operating pressure in bar [C = 1,25] |
Gas max. operating pressure in bar [C = 2] |
|||||||
41 | 20 | 4 | – | |||||||
33 | 16 | 5 | – | |||||||
26 | 12,5 | 6 | – | |||||||
21 | 10 | 8 | – | |||||||
17 | 8 | 10 | 5 | |||||||
13,6 | 6,3 | 12,5 | – | |||||||
11 | 5 | 16 | 10 | |||||||
9 | 4 | 20 | 12,5* | |||||||
7,4 | 3,2 | 25 | – |
*only valid for the Russian market
Pressure reduction factor

Pressure reduction factor 0,5

Pressure reduction factor 0,6

Pressure reduction factor 0,75

Pressure reduction factor 0,8
Due consideration of the pressure reducing factor (ƒB) the maximum allowable operating pressure PFA (20°C water) can be determined.
The following formula is used for this: